STANDARD SPECIFICATIONS:
For Series CX Solenoid Pilot Controlled Valves.
Pilot Solenoid: DC power. Rated for continuous duty.
Standard Voltages: 24 volts DC; 120 volts AC, 50/60 Hz.
Power Consumption: Per Solenoid: 3 VA on AC; 2.5 watts on DC.
Ambient/Media Temperature: 40° to 120°F (4° to 50°C).
Flow Media: Filtered air; 5 micron recommended.
Inlet Pressure: Vacuum to 145 psig (10 bar).
Pilot Pressure: 30 to 145 psig (2 to 10 bar). Must be equal to
or greater than inlet pressure. For vacuum service models a pilot
pressure of at least 30 psig (2 bar) is required.
Override: Standard on 2/2 valves, 3/8” thru 1” bodies and 3/2
valves, 3/8” and 1/2” bodies. Non-Locking.
Port Threads: NPT standard, BSPP.
Note: For fluid applications, consult ROSS.
Series CX Leak Test Valves & Manifolds
IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on the inside back cover.
Dimensions – inches (mm)
Leak Test Valves
Leak Test Manifolds
Dimensions – inches (mm)
Operator: External pilot, solenoid actuated.
Applications: Pressure Decay, Bypass Fill and
Pressure isolation.
2/2 Valves, normally closed (NC) or normally open (NO)
Operator: External pilot, solenoid actuated.
Applications: Directional control, Pressure isolation.
The CX 2/2 valve completes the product line with a leak tight high flow 2-way valve that is suitable for any application.
Port Sizes Valve Model Number* Avg.
Dimensions inches (mm) Weight
1 2 NC NO C
V
Length Width Height NC Height NO lb (kg)
1/2 3/8 CX14NA37501W CX24NA37501W 3.5 3.83 (97.3) 2.83 (71.9) 2.85 (72.4) 2.85 (72.4) 1.4 (0.6)
1/2 1/2 CX14NA47501W CX24NA47501W 3.5 3.83 (97.3) 2.83 (71.9) 2.85 (72.4) 2.85 (72.4) 1.4 (0.6)
0.83
(21.1)
2.85
(72.4)
2.59
(65.8)
2
1
1.16
(29.5)
1.15
(29.2)
2.31 (58.7)
0.52
(13.2)
Pilot Port
10-32 UNF
2.83 (71.9)
3.83 (97.3)
2.83
(71.9)
1 0 1
X-1
1.82
(46.2)
0.92
(23.4)
Side Mounting
5/16-24 UNC
0.73
(18.5)
0.71
(18.0)
1.40
(35.5)
0.38
(9.7)
2.18 (55.4)
0.41
(10.3)
1.01
(55.4)
Ø 0.20
Mounting
Through-Hole
2.10
(53.2)
Complete valves-on-manifold assemblies can be ordered to fit your precise requirements.
When ordering the Dale Series CX manifold valves with different valve functions, please see page 16 for ordering information.
Port Sizes Valve Model Number* Avg.
1 2 NC NO C
V
2/2 Solenoid Pilot Controlled
1/2 3/8 CX14NA37511W CX24NA37511W 3.7
1/2 1/2 CX14NA47511W CX24NA47511W 3.7
For BSPP threads, replace “N” in the model number with a “D”, e.g., CX14DA37501W.
For 120 volts AC, 50/60 Hz, replace suffix “W” with “Z”, e.g., CP14NA37501Z.
Electrical connectors not included, see page 7 for ordering information.
Normally Open (NO)
Normally Closed (NC)
1
2
1
2
0.52
(13.2)
2
2.85
(72.4)
1.42
(36.1)
2.18
(55.4)
Ø0.20 Mounting
Through-Hole
3.83
(97.3)
2.83
(71.9)
2.13
(54.1)
Number Of Valves
X 1.46 (37.1)
0.83
(21.1)
1
1.16
(29.5)
1.15
(29.2)
2.31 (58.7)
Pilot Port
10-32 UNF
2 2 2